See
What You've Been Missing
Introducing the Next-Generation of Portable Oscilloscopes
See More with MegaZoom III Technology
Users of general-purpose portable oscilloscopes have, until now, had to work
through everyday debug tasks using oscilloscope technology from the 1990s.
Engineers need tools capable of handling today’s design challenges.
The new Agilent 5000 Series oscilloscopes tackle these needs with their deep
memory, high-definition display system, and a superior ability to capture
transient signals. As a result engineers and technicians can catch design
bugs and problems before they get to their customers and increase their own
level of productivity.
See More Events. Your chances of finding a glitch increases as the update rate increases. If a glitch occurs during the "dead time" between samples, you miss it. With MegaZoom III acquisition technology, the dead time is much smaller. This improves your chances of finding isolated events by up to 100 times, and speeds up automated test dramatically.
See More Detail Over More Time. MegaZoom III deep memory allows you to quickly zoom in on a slow event, and see the smallest detail in each cycle. MegaZoom III is not a special mode, it's always fast, always on.
High resolution mode. Offers up to 12 bits of veritcal resolution in real-time, single-shot mode. This is accomplished by serially filtering sequential data points and mapping the filtered results to the display when operating at base settings greater than 10-μs/div.
Help is at your fingertips. An embedded help system – available in 11 languages – gives you quick answers if you don’t understand a feature. Simply press and hold the corresponding front-panel key, and a screen pops up to explain its function.
Waveform math with FFT. Analysis functions include subtract, multiply, integrate, and differentiate, as well as Fast Fourier Transforms (FFT).
Peak detect. 250 ps on 500 MHz models, 500 ps on 300 MHz models and 1 ns on 100 MHz models helps you find narrow glitches.
AutoProbe interface. Automatically sets probe attenuation factors and provides power for selected Infiniium active probes, including the award-winning 1130A 1.5 GHz InfiniiMax differential active probe and 1156A 1.5 GHz single-ended active probe systems.
5-Digit hardware counter. Measures frequency up to the bandwidth of the scope.
Trigger Out. Provides an easy way to synchronize your scope to other instruments. Use the Trig Out port to connect your scope to a frequency counter for more accurate frequency measurements or to cross trigger other instruments.
Autoscale. Displays all active signals, and automatically sets the vertical, horizontal and trigger controls.
23 automatic measurements with QuickMeas. Pressing [QuickMeas] brings up the last four measurements selected. Cursors automatically track the most recently selected measurement.
NEW - Serial Trigger. The 5000 Series now offers standard triggering for I2C, SPI, CAN, LIN, and USB, as well as optional hardware-accelerated decode. Current 5000 Series owners can simply update their firmware to add the new serial triggering capability, and to accomodate the hardware-accelerated decode options. Firmware Update: Download the latest firmware from Agilent to add serial trigger capability to your DSO5000 Oscilloscope here.
HDTV Trigger. The 5000 Series supports analog HDTV/EDTV triggering for standards like 1080i, 1080p, 720p and 480p as well as standard video triggering on any line within a field, all lines, all fields, odd or even fields for NTSC, SECAM, PAL and PAL-M video signals.
Easy software upgrades. System software is stored in Flash ROM that can be upgraded from the scope's built-in USB port or LAN.
Complete Connectivity - Standard
LXI Class C Compliant. LAN eXtensions for Instrumentation (LXI) is a standards-based architecture for test systems. By specifying the interaction of system components, LXI enables fast and efficient test system creation and reconfiguration. The 5000 Series oscilloscopes follow specified LAN protocols, and adhere to LXI requirements such as a built-in Web control server, IVI-COM driver, and easy-to-use SCPI commands. The standard Agilent I/O Library Suite makes it easy to configure and integrate instruments in your system.
Includes: User, service and programmer guides, power cord, one 10:1 passive probe per scope channel (N2863A with DSO501xA/503xA, 10073C with DSO505xA), front panel cover, Agilent IO libraries suite, calibration certs. Three-year warranty.
|
|
|
Put a quote request together for our sales staff to research for you. |
|---|---|
|
Add items to your shopping cart to buy on-line. Free shipping included! |
|
Agilent Technologies DSO5012A Oscilloscope, 100 MHz, 2 CH, 2 GSa/s |
TestEquity Price $4,479
|
||
|
|
|||
|
Agilent Technologies DSO5014A Oscilloscope, 100 MHz, 4 CH, 2 GSa/s |
TestEquity Price $5,260
|
||
|
|
|||
|
Agilent Technologies DSO5032A Oscilloscope, 300 MHz, 2 CH, 2 GSa/s |
TestEquity Price $6,313
|
||
|
|
|||
|
Agilent Technologies DSO5034A Oscilloscope, 300 MHz, 4 CH, 2 GSa/s |
TestEquity Price $7,742
|
||
|
|
|||
|
Agilent Technologies DSO5052A Oscilloscope, 500 MHz, 2 CH, 4 GSa/s |
TestEquity Price $9,199
|
||
|
|
|||
|
Agilent Technologies DSO5054A Oscilloscope, 500 MHz, 4 CH, 4 GSa/s |
TestEquity Price $10,978
|
||
|
|
|||
|
N5423A (Opt. LSS) I2C and SPI Triggering & Decode For InfiniiVision 4-channel oscilloscopes only. |
TestEquity Price $1,354
|
||
|
|
|||
|
N5424A (Opt. AMS) CAN/LIN Automotive Triggering and Decode For InfiniiVision 4-channel oscilloscopes only. |
TestEquity Price $1,354
|
||
|
|
|||
|
N5454A (Opt. SGM) Segmented Memory |
TestEquity Price $1,354
|
||
|
|
|||
|
N5455A (Opt. LMT) Mask/Waveform Limit Test |
TestEquity Price $690
|
||
|
|
|||
|
N5457A (Opt. 232) RS-232/UART Triggering and Decode For InfiniiVision 4-channel oscilloscopes only. |
TestEquity Price $1,354
|
||
|
|
|||
|
N5466A InfiniiVision Firmware Upgrade Includes Measurement Statistics and Tracking Cursor features and Version 5.2 bug fixes/changes. For scopes shipped prior to January 2009. |
TestEquity Price $115
|
||
|
|
|||
|
N2762A (Opt. 080) 8 Mpts Acquisition Memory Increase acquisition depth from 1 Mpts to 8 Mpts. Upgradeable via license key. User self-installable, no tools or calibration required. Note: 8Mpts memory is now standard on new DSO5000 oscilloscopes. |
TestEquity Price $521
|
||
|
|
|||
|
N5468A (Opt. SND) I2S Triggering and Decode Option For InfiniiVision 4-channel oscilloscopes only. |
TestEquity Price $1,250
|
||
|
|
|||
|
10073C Passive Probe 10:1, 500 MHz |
TestEquity Price $353
|
||
|
|
|||
|
N2863A Passive Probe 10:1, 300 MHz |
TestEquity Price $145
|
||
|
|
|||
|
N2760A Soft Carrying Case |
TestEquity Price $309
|
||
|
|
|||
|
N2916B Rackmount Kit |
TestEquity Price $704
|
||
|
|
|||
|
N2917B Transit Case |
TestEquity Price $1,075
|
||
|
|
|||
|
U3000A Electronic Instrumentation Training Kit |
TestEquity Price $200
|
||
|
|
|||
|
Option SEC Secure Environment Mode |
TestEquity Price $411
|
||
|
|
|||
|
N5432C (Opt. FLX) FlexRay Measurements For 4-channel InfiniiVision models only. |
TestEquity Price $4,500
|
||
|
|
|||
|
N5469A (Opt. 553) MIL-STD 1553 Triggering and Decode |
TestEquity Price $1,303
|
||
|
|
|||
|
Agilent Technologies DSO7000B, MSO7000B Series InfiniiVision Oscilloscope Up to 1 GHz, 4 GSa/s, 8M, 4 + 16 Channels |
|
|
|
|
|
Agilent Technologies DSO1002A, DSO1004A, DSO1012A, DSO1014A, DSO1022A, DSO1024A Digital Storage Oscilloscopes 60 MHz to 200 MHz, 2 and 4 channels |
|
|
|
|
|
Agilent Technologies DSO6000A, MSO6000A Series InfiniiVision Digitizing & Mixed Signal Oscilloscopes Up to 1 GHz, 4 GSa/s, 8M, 4 + 16 Channels |
|
|
|
|
|
Agilent Technologies DSO9000A, MSO9000A Series Infiniium Oscilloscopes 600 MHz to 4 GHz, 500 M Record, 20 GSa/s |
|
|
|
|