TestEquity LLC New and Used Test Equipment Call Us Toll Free New Used Agilent Tektronix and more
Category >> LCR Impedance >> 1920
Brand New Test Equipment

Complete listing for QuadTech products
Printer friendly version, in a new window

QuadTech 1920 LCR Meter


QuadTech 1920 LCR Meter

Price Listing >>

  • Frequency Range 20 Hz to 1 MHz
  • 0.1% Basic Measurement Accuracy
  • Measurement Speeds Up to 40/sec
  • 20 Measurement Parameters
  • DC Resistance Measurements
  • Monitoring of DUT Voltage and Current
  • 5-Digit Measurement Resolution
  • Programmable DC Bias Voltage, 0 to 2 V
  • Constant Voltage (Voltage Leveling)
  • GPIB, RS-232 & Handler Interfaces, all Standard
  • Open/Short Zeroing & Cable Compensation
  • Load Correction
  • 14 Pass/Fail Bins
  • Keypad Lockout
The 1920 is a high performance LCR Meter designed to perform fast, automated impedance measurements on a variety of electronic components and materials. The instrument has a basic accuracy specification of 0.1% for accurate test results over a wide frequency range, from 20 Hz to 1 MHz. Besides 15 impedance parameters the 1920 is also capable of measuring DC resistance as well as monitoring the voltage across or current through the device under test. The unit incorporates a distinctive sequence test mode, allowing up to 6 uniquely different tests to be performed quickly on a single start command. Additionally, the 1920 includes GPIB, RS-232, and handler interfaces, all standard.

20 Measurement Parameters
Measure and display any two of 15 impedance parameters simultaneously, with a basic accuracy of 0.1%. Additionally the 1920 can measure the DC resistance, or display the current through or voltage across a test device ensuring the operator of the real test conditions.

Wide Frequency
Over 27,000 user programmable test frequencies to fully characterize devices over the range of 20 Hz to 1 MHz.

Automatic Test Sequencing
For increased productivity and throughput the 1920 can perform up to six different tests in sequence with a single push of the start button. Each test can have different measurement parameters, test conditions and limits.

DC Bias Voltage
The instruments internal DC bias voltage source, programmable from 0 to 2 V in 1 mV steps, allows capacitors to be tested under real DC bias conditions.

Setup Storage/Recall
The test operator has the ability to store and recall, from internal memory, up to 30 single test setups and 10 sequential setups (six tests in sequence). The front panel can be locked out, with password protection, to ensure that procedures are run the same way every time.

Load Correction
Substantially improves instrument accuracy by allowing the operator to specify the value of a known standard, measure it, and apply a correction to ongoing measurements.

Programmable Source Impedance
The operator is able to set instrument source impedance at 5, 25, 50 or 100 ohms, an important feature when comparing measurements to those made on other testers. Measurement results can vary substantially based solely on the source impedance of the tester being used.

Includes power cord, instruction manual, and calibration certificate. One year warranty.



Shopping Legend

Add to quote icon Put a quote request together for our sales staff to research for you.
Add to cart icon Add items to your shopping cart to buy on-line. Free shipping included!

PRICING INFORMATION

QuadTech 1920 LCR Meter
 
TestEquity Price $4,695
spacer

OPTIONS & ACCESSORIES

1700-01 Axial/Radial Component Test Fixture
 
 TestEquity Price $265
spacer
1700-02 Axial/Radial Component Test Fixture
(Remote) 
 TestEquity Price $170
spacer
1700-03 Kelvin Clip Leads
 
 TestEquity Price $170
spacer
1700-05 Chip Component Tweezers
 
 TestEquity Price $170
spacer