Summary Specifications (18°C to 28°C
for one year) *
|
Voltage
(max load, 1 mA)
|
0 to 100 mV:
Resolution: 0.01 mV
Accuracy: 0.02% Rdg + 2 LSD
0 to 10V (source):
Resolution: 0.001V
Accuracy: 0.02% Rdg + 2 LSD
0 to 30V (measure):
Resolution: 0.001V
Accuracy: 0.02% Rdg + 2 LSD
|
mA
(max load, 1000 Ω)
|
0 to 24 mA:
Resolution:0.001 mA
Accuracy: 0.02% Rdg + 2 LSD
|
mV
(TC terminals)
|
-10.00 mV to +75.00 mV:
Resolution: 0.01 mV
Accuracy: .025% Rdg + 1 LSD
|
|
Resistance
|
0 Ω to 3200 Ω (Measure):
Resolution: 0.01 Ω to 0.1 Ω
Accuracy: 0.10 Ω to 1.0 Ω
15 Ω to 3200 Ω (Source):
Resolution: 0.01 Ω to 0.1 Ω
Accuracy: 0.10 Ω to 1.0 Ω
|
|
Loop Supply
|
24V dc:
Resolution: N/A
Accuracy: 10%
|
|
*Temperature coefficient, -10°C to 18°C, 28°C to 55°C,
±0.005% of range per °C. |
| |
| Thermocouple Accuracy Specifications
(measure or source) * |
| J |
-200 to 0°C:
Accuracy: 1.0°C
0 to 1200°C:
Accuracy: 0.7°C
|
| K |
-200 to 0°C:
Accuracy: 1.2°C
0 to 1370°C:
Accuracy: 0.8°C
|
| T |
-200 to 0°C:
Accuracy: 1.0°C
0 to 400°C:
Accuracy: 0.8°C
|
| E |
-200 to 0°C:
Accuracy: 0.9°C
0 to 950°C:
Accuracy: 0.7°C
|
| R |
-20 to 0°C:
Accuracy: 2.5°C
0 to 500°C:
Accuracy: 1.8°C
500 to 1750°C:
Accuracy: 1.4°C
|
| S |
-20 to 0°C:
Accuracy: 2.5°C
0 to 500°C:
Accuracy: 1.8°C
500 to 1750°C:
Accuracy: 1.5°C |
| B |
600 to 800°C:
Accuracy: 2.2°C
800 to 1000°C:
Accuracy: 1.8°C
1000 to 1800°C:
Accuracy: 1.4°C
|
| L |
-200 to 0°C:
Accuracy: 0.85°C
0 to 900°C:
Accuracy: 0.7°C
|
| U |
-200 to 0°C:
Accuracy: 1.1°C
0 to 400°C:
Accuracy: 0.75°C
|
| N |
-200 to 0°C:
Accuracy: 1.5 °C
0 to 1300°C:
Accuracy: 0.9°C
|
|
* (Accuracy specifications include 0.2°C cold junction uncertainty)
|
| Thermocouple Resolution |
| J, K, T, E, L, N, U |
0.1°C, 0.1°F |
| B, R, S |
1°C, 1°F |
| |
| RTD Ranges and Accuracy Specifications
* |
| Ni 120 |
-80°C to 260°C:
Measure: 0.2°C
Source: 0.2°C
|
| Pt 100 - 385 |
-200°C to 800°C:
Measure: 0.33°C
Source: 0.33°C |
| Pt 100 - 3926 |
-200°C to 630°C:
Measure: 0.3°C
Source: 0.3°C |
| Pt 100 - 3916 (JIS) |
-200°C to 630°C:
Measure: 0.3°C
Source: 0.3°C
|
| Pt 200 - 385 |
-200°C to 250°C:
Measure: 0.2°C
Source: 0.2°C
250°C to 630°C:
Measure: 0.8°C
Accuracy: 0.8°C
|
| Pt 500 - 385 |
-200°C to 500°C:
Measure: 0.3°C
Source: 0.3°C
500°C to 630°C:
Measure: 0.4°C
Accuracy: 0.4°C
|
| Pt 1000 - 385 |
-200°C to 100°C
Measure: 0.2°C
Source: 0.2°C
100°C to 630°C
Measure: 0.3°C
Source: 0.2°C
|
|
* Note: Measure (4 wire)
|
| RTD Resolution |
0.1°C, 0.1°F |
| |
| General Specifications
|
| Maximum voltage |
30V |
| Storage Temperature |
-20°C to 71°C |
| Operating Temperature |
-10°C to 55°C |
| Relative Humidity |
90% (10°C to 30°C); 75% (30°C to 40°C);
45% (40°C to 50°C); 35% (50°C to 55°C) |
| Vibration |
Random, 2g, 5-500 Hz |
| Safety |
CSA C22.2 No. 1010.1:1992 |
| EMC |
EN50082-1:1992 and EN55022:1994 Class B |
| Size |
96 x 200 x 47 mm (3.8 x 7.9 x 1.9 inches)
|
| Weight |
650g (23oz) |
| Battery |
Four AA alkaline batteries. Battery life:
25 hours typical |
| Warranty |
Three years |