Fluke

Fluke 60 Series Handheld Infrared Thermometer Selection Guide


  Fluke 61 Fluke 65 Fluke 62 Fluke 63 Fluke 66 Fluke 68

Fluke 61

Fluke 65

Fluke 62
Fluke 63
Fluke 66
Fluke 68
Backlight
Yes
Yes
Yes
Yes
Yes
Yes
Hold
Yes
Yes
Yes
Yes
Yes
Yes
Range
-18 to 275 ºC
(-0 to 525 ºF)
-40 to 500 ºC
(-40 to 932 ºF)
-30 to 500 ºC
(-20º to 932 ºF)
-32 to 545 ºC
(-25 to 999 ºF)
-32 to 600 ºC
(-25 to 1100 ºF)
-32 to 760 ºC
(-25 to 1400 ºF)
MIN/MAX/AVG
N/A
MIN/MAX
MAX
MAX
All
All
Datalogging
N/A
N/A
N/A
N/A
Yes
Yes
Distance to spot ratio
8:1
8:1
10:1 @80% energy
12:1
30:1
50:1
Hi-Lo Alarm
N/A
N/A
N/A
Yes
Yes
Yes
Optional RTD probe
N/A
N/A
N/A
N/A
Yes
Yes
Emissivity
Fixed at 0.95
Fixed at 0.95
Fixed at 0.95
Fixed at 0.95
Digitally adjustable
(0.1 to 1.0 by 0.01)
Digitally adjustable
(0.1 to 1.0 by 0.01)
Model
Fluke 61
Fluke 65
Fluke 62
Fluke 63
Fluke 66
Fluke 68

 

Measurement Accuracy
Fluke 61

-18 °C (0 °F) to -1 °C (30 °F) : ± 3 °C (5 °F)
above -1 °C (30 °F) to 275 °C (525 °F) : ± 2% of reading or 2 °C (3.5 °F)
(With the instrument stable between 23-25 °C)

Fluke 65 Above 0 ºC (32 ºF) : ± 2 ºC (± 4 ºF)
Below 0 ºC (32 ºF) : ± 5 ºC (± 9 ºF)
(With instrument stable at 23ºC ± 3 ºC)
Fluke 62 10 ºC to 30 ºC (50 ºF to 86 ºF) : ± 1 ºC (2 ºF)
Outside 10 ºC to 30 ºC (50 ºF to 86 ºF) : ± 1.5 ºC (3 ºF)
or ± 1.5 % of reading, whichever is greater
Fluke 63, 66, 68 -32 to -26 ºC (-25 to -15 ºF) : ±3 ºC (±5 ºF)
-26 to -18 ºC (-15 to 0 ºF) : ±2.5 ºC (±4 ºF)
-18 to 23 ºC (-0 to 73 ºF) : ±2 ºC (±3 ºF)
For targets above 23 ºC (73 ºF): ±1% of reading
or ±1 ºC (±2 ºF), whichever is greater

Features

Fluke 61
* Bright laser beam provides easy targeting
* Display clearly supplies data at a glance
* Shock-absorbing holster increases ruggedness
* 0.2 °C (0. 5 °F) resolution up to 275 °C (525 °F)
* Backlight illuminates the screen in the dark
* Automatic sleep mode after 7 seconds extends battery life
* Alkaline batteries provide 4000 typical measurements

Fluke 65
* Rugged electronics and case with holster
* Bright laser beam provides easy targeting
* Large dual display LCD display clearly supplies data at a glance
* 0.1º resolution up to 200º (1º resolution above 200º)
* Quality backlight illuminates the screen in the dark
* MIN/MAX provides the variation in any measurement
* Store and recall any single temperature
* Automatic sleep mode after 15 seconds extends battery life
* Includes C50 soft carrying case, batteries and instruction sheet
* Measures up to 500 ºC (932 °F)

Fluke 62
* Single point offset laser sighting
* Best accuracy in its class: + 1% of reading
* Holds temperature readings for 7 seconds
* Dual displays shows current and MAX measurements simultaneously
* Backlit display for poorly lit areas
* Comfortable ergonomic handle with protective rubber boot for added durability
* Fitted carrying case
* Robust, award winning design
* Wide temperature range from -30º to 500ºC (–20º to 932ºF)

Fluke 63
* High-resolution optics
* High accuracy: 1 % and repeatability: 0.5 %
* MAX temperature display
* Laser targeting
* Backlit display
* Expanded measurement range up to 535 °C (999 °F)

Fluke 66
* Laser guided sighting system for easy targeting with 1 % accuracy
* 12-point data logging
* Advanced optics to measure smaller targets at greater distances
* Adjustable emissivity for more accurate temperature measurements
* Selectable MAX, MIN, DIF and AVG functions that display values instantly with Hi/Lo Alarm
* Expanded measurement range up to 600 ºC (1100 ºF)
* Optional probe accessory available for dual contact and non-contact temperature measurements

Fluke 68
* Laser guided sighting system for easy targeting with 1 % accuracy
* 12-point data logging
* Advanced optics to measure smaller targets at greater distances
* Adjustable emissivity for more accurate temperature measurements
* Selectable MAX, MIN, DIF and AVG functions that display values instantly with Hi/Lo Alarm
* Expanded measurement range up to 760 ºC (1400 ºF)
* Optional probe accessory available for dual contact and non-contact temperature measurements