Model 115 Temperature Chamber Specifications
<< Back to Model 115 Product Page
| Temperature Range |
-73°C to +175°C |
| Control Tolerance |
±0.2°C (Measured at the control
sensor after stabilization) |
| Uniformity |
±0.5°C (Variations throughout
the chamber after stabilization) |
| Heat Up Transition Time* |
5°C/minute typical |
| Cool Down Transition Time* |
| Start
Temp |
End Temp |
| +23°C |
0°C |
-40°C |
-55°C |
-65°C |
-73°C |
| +23°C |
----- |
5 min |
20 min |
30 min |
40 min |
Ultimate |
| +85°C |
16 min |
25 min |
45 min |
57 min |
69 min |
Ultimate |
Rate Of Change
To calculate rate of change for a particular condition, take the difference
between the Start Temp and End Temp and divide by the Transition
Time.
Cool Down Example: From +85°C to -40°C = 125°C / 45
min = 2.78°C/min. |
| *Note: Transition times are measured after a 1 hour
soak at the respective start temperature with an empty chamber, as indicated
on the temperature controller, 23°C ambient. |
| Live Load Capacity |
| +23°C |
0°C |
-40°C |
-55°C |
-65°C |
| 300 Watts |
255 Watts |
160 Watts |
110 Watts |
80 Watts |
| Refrigeration and Heating
System |
| High Stage Refrigerant |
R-404A (Dupont HP-62) |
| Low Stage Refrigerant |
R-508B (Dupont SUVA-95) |
| Compressors |
1/2 HP x 1/3 HP Copeland hermetic compressors in a cascade configuration. |
| Condenser |
Air Cooled |
| Heat of Rejection |
4,000 BTUH (maximum rated chamber load at maximum cooling
rate from high temperature soak) |
| Heater Power |
600 Watts |
| Instrumentation |
| Temperature Controller |
256 step, 40 profile, ramp and soak programmable memory. RS-232/485 interface.
More details >> |
|
| Limit Controller |
Independent high and low temperature limits. Triggers an audible alarm
and shuts down the chamber. |
| Power Requirements |
| Input Voltage |
120 V nominal (110 to 126 VAC), 60 Hz, 1 PH
Max Current Draw 15 A, Recommended Minimum Service 20 A
Model 115-EX export version available with 230V, 50Hz, 8A input |
Power Cord
and Plug |
| 6' Power cord supplied with a molded NEMA 5-20P plug. |
 |
Plugs into a standard NEMA 5-20R receptacle.
Use of an extension cord is not recommended. |
 |
Model 115-EX export version is supplied with power cord for destination
country. |
| Physical
Characteristics and Safety |
| Inside Dimensions |
16" W x 12" H x 14" D (1.55 Cubic feet)
406 mm W x 305 mm H x 353 mm D (44 liters) |
| Outside Dimensions |
Benchtop Model 115B
24" W x 44" H x 26" D (nominal)
610 mm W x 1118 mm H x 660 mm D
Floor Model 115F
24" W x 61" H x 26" D (nominal)
610 mm W x 1549 mm H x 660 mm D |
| Minimum Installed Clearance |
6" from the left and right side
12" from the rear |
| Window Viewing Area |
8" W x 6" H |
| Access Ports |
3" (2.83" inside diameter) supplied on all new Model 115 chambers. Port on left and right side (two total)
Supplied with silicone foam port plugs |
| Weight |
Benchtop Model 115B
Chamber Weight: 275 pounds
Shipping Weight: 320 pounds
Floor Model 115F
Chamber Weight: 300 pounds
Shipping Weight: 345 pounds |
| Sound Level |
52 dBA in cooling mode (A-weighted, measured 36" from the front
surface, 63" from the floor, in a free-standing environment) |
| CE Mark |
Export version, Model 115-EX is CE Marked |
NOTE: Performance is typical and based on operation at 23°C
(73°F) ambient and nominal input voltage. Designed for use in a normal
conditioned laboratory. Operation at higher ambient temperatures may
result in decreased cooling performance. Additional ports and shelves
will also affect performance. Operation above 30°C (85°F) or
below 16°C (60°F) ambient is not recommended.
Due to continuous product development, specifications are subject to
change without notice. |
<< Back to Model 115 Product Page
|