TestEquity Inc - http://www.testequity.com/ To order, call us at 800-950-3457
or visit us on the web: www.TestEquity.com

Chroma 61600 Detailed Specifications


Model 61601 61602 61603 61604 61605
Output Rating - AC (*Note: Output Voltage x Output Current cannot exceed Max. Power rating.)
Max. Power* 500 VA 1,000 VA 1,500 VA 2,000 VA 4,000 VA
Voltage Ranges 150 V / 300 V / Auto
Accuracy 0.2% +0.2% F.S.
Resolution 0.1 V
Distortion 0.3% @ 50/60 Hz
1%, 15 Hz to 1 kHz
0.3% @ 50/60 Hz
1%, 15 Hz to 800 Hz
Line Regulation 0.1%
Load Regulation 0.2%
Max. Current*
r.m.s. (150 V / 300 V)
peak (150 V / 300 V)

4 A / 2 A
24 A / 12 A

8 A / 4 A
48 A / 24 A

12 A / 6 A
72 A / 36 A

16 A / 8 A
96 A / 48 A

32 A / 16 A
192 A / 96 A
Frequency
Range DC, 15 Hz to 1 kHz DC, 15 to 800 Hz
Accuracy 0.15%
Output Rating - DC (*Note: Output Voltage x Output Current cannot exceed Max. Power rating.)
Max. Power* 250 W 500 W 750 W 1,000 W 2,000 W
Voltage* 212 V / 424 V
Current* (212 V / 424 V) 2 A / 1 A 4 A / 2 A 6 A / 3 A 8 A / 4 A 8 A / 4 A
Input Rating
Voltage Range 90 to 250 V, 1 PH 190 to 250 V, 3 PH
Frequency Range 47 to 63 Hz
Current 10 A Max.@ 90 V 18 A Max.@ 90 V 22 A Max.@ 90 V 28 A Max.@ 90 V 14 A Max. @ 190 V
Power Factor 0.97 Min. 0.97 Min. 0.98 Min. 0.98 Min. 0.98 Min.
Voltage Measurement
Ranges 150 V / 300 V
Accuracy 0.2% +0.2% F.S.
Resolution 0.1 V
Current Measurement
Range peak 48 A 48 A 96 A 96 A 192 A
Accuracy r.m.s. 0.2% +0.1% F.S.
Accuracy peak 0.2% +0.2% F.S.
Power Measurement
Accuracy 0.4% F.S. (CF <6)
Resolution 0.1 W
Environmental
Operating Temp. 0 to 40°C
Storage Temp. -40 to +85°C
Safety/EMC CE. including EMC & LVD
Model 61601 61602 61603 61604 61605

 

 
TestEquity Inc - http://www.testequity.com/ To order, call us at 800-950-3457
or visit us on the web: www.TestEquity.com