Zero to rated voltage continuously variable with front panel voltage
knob
|
|
Zero to rated current continuously variable with front panel current
knob
|
CV: ±0.01% + 2 mV
CC: ±0.01% + 2 mA
|
CV: ±0.01% + 2 mV
CC: <10 mA @ 100 W; <1 mVrms @ above 100 W
|
CV: <0.5 mVrms @ 100 W; <1 mVrms @ above 100 W
CC: <1 mArms @ 100 W; <3 mArms @ above 100 W
|
|
<100 µS to within 0.1% of set voltage (50% to 100% load change)
|
|
<2 mΩ + 2 mH
|
|
0 to +40°C ambient temperature
|
Analog Meter: 3% of full scale
Digital Meter: < 0.1% + 2 digits |
|
Automatic crossover from CV to CC mode
|
|
Different models can be placed in series to increase output up to
240 VDC
|
|
Another identical model number can be paralleled to increase output
to 24 Amps
|
|
100 / 120 / 220 / 240 ± 10% VAC; 50 / 60 Hz, single phase
|
|
Power cord; hook-up leads; instruction manual
|
Output: 5 V ± 0.25 V
Regulation: < 10 mV
Ripple & Noise: < 2 mVrms
|
|
± 0.2% + 10 mV
|
|
Two fully independent variable supplies at rated voltage and current
and a fixed 5 V / 5 A supply
|
One variable suply with 2X rated voltage output at rated current. Or,
one dual polarity tracking supply with rated output and current.
Plus, a fixed 5 V / 5 A supply
|
One variable supply with rated voltage at 2X rated current and a
fixed 5 V / 5 A supply
|