| Constant Voltage Mode (CH1, CH2) |
Line Regulation |
< 0.01% + 3mV |
| Load Regulation |
< 0.01% + 3mV (rating current < 3A) |
| < 0.02% + 5mV (rating current > 3A) |
| Ripple & Noise |
< 1mVrms (5Hz - 1MHz) |
| Recovery Time |
< 100µS (50% Load change, Minimum load 0.5A) |
| Constant Current Mode (CH1, CH2) |
Line Regulation |
< 0.2% + 3mA |
| Load Regulation |
< 0.2% + 3mA |
| Ripple & Noise |
< 3mArms |
Tracking Mode
(CH1, CH2) |
Tracking Error |
< 0.5% + 3mV of the Master |
| Series Regulation |
< 300mV |
| Load Regulation |
< 0.01% + 3mV |
| Ripple & Noise |
< 2mVrms (5Hz - 1MHz) |
GSP-4303
2.2V - 5.2V Output (CH3)
GPS-3303
5V Fixed Output (CH3) |
Line Regulation |
< 5mV |
| Load Regulation |
< 15mV |
| Ripple & Noise |
< 2mVrms (5Hz - 1MHz) |
| Voltage Accuracy |
±5% reading |
| Current Output |
GPS-4303: 3A
GSP-3303: 1A |
GPS-4303
8V - 15V Output (CH4) |
Line Regulation |
< 5mV |
| Load Regulation |
< 10mV |
| Ripple & Noise |
< 2mVrms (5Hz - 1MHz) |
| Voltage Accuracy |
±5% reading |
| Current Output |
1A |
| Digital Meters |
3 digits 0.5" LED display
GPS-4303/3303 Out ON Accuracy ±(0.5% rdg + 2 digits)
GPS-4303/3303 Out OFF Accuracy ±(0.5% rdg + 8 digits)
GPS-2303 Accuracy ±(0.5% rdg + 2 digits) |
| Insulation |
Chassis and Terminal |
> DC 500V / 20 Megohms |
| Chassis and AC Cord |
> DC 500V / 30 Megohms |
| Power Source |
AC 100V/120V/220V/240V ±10%, 50/60Hz |
| Accessories |
Instruction manual, power cord, test lead set for each
output. |
| Dimensions & Weight |
10.2"W x 5.8"H x 10.6"D, Approx. 15.4 lbs.
255W x 145H x 265D mm, Approx. 7 kg |