TestEquity Inc - http://www.testequity.com/ To order, call us at 800-950-3457
or visit us on the web: www.TestEquity.com

Fluke 77-4 Handheld Digital Multimeter - Specifications


Specifications
Voltage DC
Range: 6.000V - 1000V
Best Accuracy: ± (0.3% + 1)
Best Resolution: 0.1 mV
Voltage AC
Range: 600.0 mV-1000V
Best Accuracy: ± (2.0% + 2)
Best Resolution: 1.0 mV
Amps AC
Range: 60.00 mA – 10A
Best Accuracy: ± (1.5% + 2)
Best Resolution: 0.01mA
Amps DC
Range: 60.00 mA – 10A
Best Accuracy: ± (2.5% + 2)
Best Resolution: 0.01 mA
Resistance
Range: 600.0 Ω - 50 MΩ
Best Accuracy: ± (0.5% + 1)
Best Resolution: 0.1Ω
Capacitance
Range: 1nF- 9,999 µF
Best Accuracy: ± (1.2% + 2)
Best Resolution: 1 nF
Frequency
Range: 99.99Hz- 99.99kHz
Best Accuracy: ± (0.1% + 1)
Best Resolution: 0.01Hz
Safety
ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV
Certifications
CSA, TÜV (EN61010), UL, Π, ; (N10140),VDE

 

General Specifications
Maximum voltage between any terminal and earth ground
1000V
Surge protection
8 kV peak per IEC 61010
Ω Fuse for mA inputs
440 mA, 1000 V FAST Fuse
Ω Fuse for A inputs
11 A, 1000 V FAST Fuse
Display
Digital: 6000 counts, updates 4/sec
Bar Graph: 33 segments; Updates 32/sec
Frequency: 10,000 counts
Capacitance: 1,000 counts
Altitude
Operating: 2,000 meters
Storage: 12,000 meters
Temperature
Operating: -10°C to +50°C
Storage: -40°C to +60°C
Temperature Coefficient
0.1 X (specified accuracy /°C (< 18°C or > 28°C)
Electromagnetic Compatibility (EN 61326-1:1997)
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5°C (9°F)
Relative Humidity (Maximum Non-condensing)
90% to 35°C
75% to 40°C
45% to 50°C
Battery Life
400 Hours Typical (Alkaline)
Size
Height: 4.3 cm
Width: 9 cm
Length: 18.5 cm
Weight
420 g

 

 
TestEquity Inc - http://www.testequity.com/ To order, call us at 800-950-3457