TestEquity Inc - http://www.testequity.com/ To order, call us at 800-950-3457
or visit us on the web: www.TestEquity.com

Agilent USB Data Acquisition Selection Guide


Product Family   U2300A Series Multifunction DAQ  U2500A Series Simultaneous Sampling DAQ  U2100A Isolated DIO  U2600A Isolated DIO  U2802A Signal Conditioner
Number of Models
Analog Input          
Channels/Module, Max. 64  -  31 
Sampling Rate, Max. Up to 3 MSa/s (single channel)
Up to 1 MSa/s* 
 Up to 2 MSa/s/ch  -  -  Up to 500 KSa/s** 
Resolution up to 16-bit  up to 16-bit  -  -  Up to 16-bit** 
Input Voltage, Max. 10V  10V  -  -  10V** 
Simultaneous Sampling Yes  - 
On-board Memory 8 MSa  8 MSa  -  -  - 
Thermocouple Signal Conditioning -  -  -  -  Yes 
Analog Output          
Channels/Module, Max. -  -  2** 
Update Rate, Max. 1 MSa/s  1 MSa/s  -  -  1 MSa/s** 
Resolution Up to 16-bit  12-bit  -  -  12-bit** 
Output Voltage, Max. 10V  10V  -  -  10V** 
Digital I/O          
Channels/Module, Max. 24  24  32  64  - 
Input Levels, Max. 5V  5V  24V  24V  - 
Output Levels, Max. 5V  5V  24V  35V  - 
Counter          
Channels -  -  - 
Max. Count (231-1) bits  (231-1) bits  -  -  - 
Software and Drivers          
Agilent Measurement Manager Yes  Yes  -  Yes  Yes 
Agilent DIO Diagnostics -  -  Yes  -  - 
IVI-COM Yes  Yes  Yes  Yes  Yes 
Agilent VEE Yes  Yes  Yes  Yes  Yes 
Compatibility with U2781A Yes  Yes  -  Yes  - 
Synchronization Between Modules  Yes  Yes  -  Yes  - 

* Aggregate sampling rate
** Dependant on U2300A module selected


 

 
TestEquity Inc - http://www.testequity.com/ To order, call us at 800-950-3457