Fluke 773 Milliamp Process Clamp Meter

16631.3 MFG #: 773
$0.00 / EA
  • Manufacturer: Fluke
  • Condition: New
  • Family Models: Fluke 773

QTY
  • Description

    • Best in class 0.2% accuracy
    • 0.01 mA resolution and sensitivity
    • Measure 4 to 20 mA signals without ”breaking the loop”
    • Measure mA signals for PLC and control system analog I/O
    • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
    • Measurement Spotlight illuminates hard to see wires in dark enclosures
    • Detachable clamp with extension cable for measurements in tight locations
    • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
    • Automatically change the 4 to 20 mA output for remote testing
    • Power saving features, auto-off, backlight timeout extend battery life
    • Hold function captures and displays changing measurements
    • Measure 4 to 20 mA signals with in-circuit measurement
    Fluke Current Clamp Meters
    Environmental Specifications
    Diameter of measurable conductor 0.177" or 4.5 mm max
    Operating temperature -10 to 50ºC
    Storage Temperature -25 to 60ºC
    Operating Humidity < 90% @ <30 ºC, < 75% @ 30 to 55ºC
    Operating Altitude 0 to 2000 m
    IP Rating IP 40
    Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
    Weight 410 g, (14.4 oz)
    Vibration Random 2 g, 5 to 500 Hz
    Shock 1 meter drop test (except the jaw)
    EMI/RFI Meets EN61326-1
    Note: For current measurement w/ JAW, add 1mA to
    specification for EMC field strengths of 1V/m up to 3V/m.
    Temperature Coefficient 0.01% ºC
    (<18ºC or > 28ºC)
    Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
    Warranty Three years for electronics
    one year for cable and clamp assembly

    Functional Specifications
    mA measurement
    (Measured by clamp) 771/772/773
    Resolution and Range: 0 to 20.99 mA
    Accuracy: 0.2%+2 counts
    Resolution and Range: 21.0 mA to 100.0 mA
    Accuracy: 1% + 5 counts
    mA measurement
    (Measured in series with test jacks) 772/773
    Resolution and Range: 0 to 24.00 mA
    Accuracy: 0.2% + 2counts
    mA source (Maximum mA Drive:
    24 mA into 1,000 ohms)
    Resolution and Range: 0 to 24.00 mA
    Accuracy: 0.2% + 2counts
    mA simulate
    (Maximum voltage 50 V dc)

    Resolution and Range: 0 to 24.00 mA
    Accuracy: 0.2% + 2counts

    Voltage source (2 mA maximum drive current) Resolution and Range: 0 to 10.00 V dc
    Accuracy: 0.2% + 2counts
    Voltatge Mesaure Resolution and Range: 0 to 30.00 V dc
    Accuracy: 0.2% + 2counts

    What’s the difference between the 77X models?

    Fluke 771 Fluke 772 Fluke 773
    Non-contact mA loop measurement Integrated mA loop troubleshooting Advanced process troubleshooting
    mA measure, jaw
    mA measure, in circuit
    Loop power
    mA source
    DCV measure
    DCV source
    mA scaled output
    mA in / out

    California Safe Drinking Water and Toxic Enforcement Act of 1986 (Prop 65) Warning