Hioki MR8880-20 Memory Recorder

19309.2 MFG #: MR8880-20
$0.00 / EA
  • Condition: New
  • Manufacturer: Hioki

QTY
  • Description

    • Measure 3-phase power lines w/4 channels of input
    • Simple operation with the Presets configuration navigator
    • Print measurement data on-site with the optional printer
    • Real-time recording
    • Isolated analog input channel
    • Max. sampling speed 1 MS/sec
    • USB 2.0 memory
    • Ships w/AC adapter Z1002 (1), Alkaline battery box (1) Strap (1), USB cable (1), Wave viewer software (1)
    • 1-Year warranty

    Capture High- to Low-Voltage Signals in a Single Device

    Thanks to its safe CAT III 600V class design, the MR8880-20 can directly measure high voltages of up to 600 V at demanding plants and other facilities. The recorder also features an extended operating temperature range of -10 °C to 50 °C and complies with JIS automotive vibration standards, demonstrating its ability to withstand the harsh measurement environments associated with automotive development.

    Basic specifications
    Measurement functionality • High-speed function (high-speed recording)
    • Real-time function (real-time recording)
    No. of input channels 4 channels of analog input + 8 channels of logic input (standard)
    *Analog input channels are isolated from one another and other device circuitry. Logic input channels share a common ground with the device.
    Max. sampling speed 1 MS/sec (1 μs period; all channels sampled simultaneously)
    Internal memory capacity 14 bits × 1 Mword per channel (1 word = 2 bytes, not expandable)
    External memory • CF card slot × 1 (up to 2 GB; supported formats: FAT/FAT32)
    • USB memory × 1 (USB 2.0 Standard-A receptacle)
    Communications interfaces USB 2.0 Mini-B receptacle × 1
    Functionality: Device configuration and measurement using communications commands; transfer of files from CF/USB memory to a computer (USB drive mode)
    Operating environment
    (non-condensing)
    • Operating temperature range: -10°C to 50°C
    • Operating humidity range: 80% RH or less at -10°C to 40°C, 60% RH or less at 40°C to 45°C, 50% RH or less at 45°C to 50°C
    • When powering the instrument with the Z1000 battery: 0°C to 40°C, 80% RH or less
    • When charging the Z1000 battery: 10°C to 40°C, 80% RH or less
    Storage environment (non-condensing) • Storage temperature range: -20°C to 60°C
    • Storage humidity range: 80% RH or less at -20°C to 40°C, 60% RH or less at 40°C to 45°C, 50% RH or less at 45°C to 60°C
    • Z1000 battery: -20°C to 40°C, 80% RH or less

    Please see Data Sheet for complete specifications