    Comprehensive tools that speed every stage of debug
    Designing with today's faster data rates and tighter timing margins requires an oscilloscope with outstanding signal acquisition performance and analysis capabilities. Tektronix DPO/MSO5000B Series oscilloscopes provide exceptional signal fidelity, with 2 GHz bandwidth and 10 GS/s sample rate, along with advanced analysis and math capabilities, on your bench and in your lab. Run Windows-based analysis software right on the oscilloscope. Point and click Visual Triggers enable you to capture complex signals with ease. MSO models include 16 digital timing channels, and all models can be equipped to decode common serial protocols, providing a comprehensive view of your systems.

    Mixed signal design and analysis (MSO Models)
    The MSO5000B Series mixed-signal oscilloscopes provide 16 digital channels. These channels are tightly integrated into the oscilloscope's user interface, simplifying operation and making it possible to solve mixed-signal issues easily. MSO functionality can also be added later as a user upgrade (Option MSOE).

    Accurate high-speed probing
    The TPP Series probes, included standard with every DPO/DPO5000B Series oscilloscope, provide up to 1 GHz of analog bandwidth, and less than 4 pF of capacitive loading. The extremely low capacitive loading minimizes adverse effects on your circuits and is more forgiving of longer ground leads. And with the probe's wide bandwidth, you can see the high frequency components in your signal, which is critical for high-speed applications.

    Long record length
    With a standard record length of 25M/channel, (optional up to 250 M point record length), you can capture many events of interest, even thousands of serial packets, in a single acquisition for further analysis. Unlike other oscilloscopes in its class, the DPO/MSO5000B provides flexible setup of both record length and sampling rate to ensure optimum resolution.

    Fast discovery
    The DPO/MSO5000B Series offers the industry's most complete performance to capture and isolate events, providing fast insight into the real operation of your device. Tektronix proprietary FastAcqtechnology delivers a fast waveform capture - greater than 250,000 waveforms per second that enables you to see glitches and other infrequent transients within seconds.

    Segmented memory
    Segmented Memory mode enables you to select up to 290,000 memory segments with a trigger capture rate of over 310,000 triggers per second. Beyond memory flexibility, segments are time stamped and can be viewed individually or as an overlay and analyzed using advanced features like protocol decoding.

    MagniVu™ high-speed acquisition
    The main digital acquisition mode on the DPO/MSO5000B Series will capture up to 40 M points at 500 MS/s (2 ns resolution). In addition to the main record, the DPO/MSO5000B provides an ultra high-resolution record called MagniVu which acquires 10,000 points at up to 16.5 GS/s (60.6 ps resolution). Both the main and MagniVu waveforms are acquired on every trigger and either can be displayed at any time, running or stopped.

    Navigation and search
    The DPO/MSO5000B Series offers the industry's most comprehensive search and waveform navigation with its innovative Wave Inspector controls. These controls speed panning and zooming through your record. With a unique force-feedback system, you can move from one end of your record to the other in just seconds.

    Visual Trigger and Search makes the identification of the desired waveform events quick and easy by scanning through all waveform acquisitions and comparing them to on-screen areas (geometric shapes). Areas can be created using a variety of shapes including triangles, rectangles, hexagons, trapezoids, and user specified shapes.

    Additional DPO/MSO5000B Series Key Features

    • Wave Inspector navigation with Advanced Search and Mark
    • Parallel and serial bus triggering and decode
    • 16 digital channels (MSO models)
    • Long record length (standard record length of 25M/channel, optional up to 125M points/channel)
    • Standard high-impedance, low-capacitance passive voltage probing with up to 1 GHz bandwidth
    • FastAcq maximum waveform capture rate of > 250m000 waveforms per second
    • FastFrame segmented memory acquisition
    • DPO intensity graded display with color or gray scale
    • Optional analysis for jitter and eye diagram measurements, serial compliance test, power measurements, limit test, mask test, and DDR memory bus analysis
    • Field-upgradeable MSO capability
    • Capabilities previously optional, now included standard: ASM, DJE, LT, ST-CUST, VET, 2RL

    All models include: one passive voltage probe per analog channel (TPP0500 500MHz, 10X, 3,9pF for 500 MHz and 350 MHz models TPP1000 1 GHz, 10X, 3.9pF for 2 GHz and 1 GHz models), front cover, touchscreen stylus, user's manual, accessory pouch, mouse, calibration certificate documenting measurement traceability to National Metrology Institute(s), Z 540-1 compliance and ISO9001. MSO Models also include: one P6616 16-channel logic probe and a logic probe accessory kit.

    DPO5000, MSO5000 Digital Phosphor, Mixed Signal Oscilloscopes

    Model DPO5034B DPO5054B DPO5104B DPO5204B MSO5034B MSO5054B MSO5104B MSO5204B
    Analog Bandwidth 350 MHz 500 MHz 1 GHz 2 GHz 350 MHz 500 MHz 1 GHz 2 GHz
    Sample Rate 5 GS/s 5 GS/s 5-10 GS/s 5-10 GS/s 5 GS/s 5 GS/s 5-10 GS/s 5-10 GS/s
    Record Length 25 M 25 M 25 M (4 ch)
    50 M (1 or 2 ch)
    25 M (4 ch)
    50 M (1 or 2 ch)
    25 M 25 M 25 M (4 ch)
    50 M (1 or 2 ch)
    25 M (4 ch)
    50 M (1 or 2 ch)
    Rise Time 1 ns 700 ps 350 ps 175 ps 1 ns 700 ps 350 ps 175 ps
    Channels (A/D) 4 4 4 4 4+16 4+16 4+16 4+16

    Please refer to Data Sheet for complete specifications.

    • 2 GHz, 1 GHz, 500 MHz, and 350 MHz bandwidth models
    • Up to 10 GS/s real-time sample rate on one or two channels and up to 5 GS/s on all four channels
    • Up to 250 megapoint record length with MultiView zoom
    • >250,000 wfms/s max. waveform capture rate with FastAcqacquisition
    • FastFrame segmented memory acquisition mode with up to 290,000 segments and >310,000 waveforms per second capture rate
    • Standard 10 M? passive voltage probes with less than 4 pF capacitive loading and 500 MHz or 1 GHz analog bandwidth
    • >11 bits vertical resolution using HiRes sampling
    • User-selectable bandwidth limit and DSP filters for lower noise and better measurement accuracy
    • Optional Serial Triggering and Technology-Specific Analysis
    • Standard removable hard disk drive (?480 GB)
    • Microsoft Windows 7 64-bit Operating System
    • USB, LAN (LXI-C)
    • One-year warranty

    ManufacturerModelDescription
    TektronixOpt. PS2Power Solution Bundle - DPO/MSO5000B Series DPOPWR, THDP0200 High Voltage Differential Probe, TCP0030A AC/DC Current Probe, 067-1686-XX deskew fixture. MUST BE ORDERED WITH DPO/MSO5000B SERIES OSCILLOSCOPE TO GET THIS BUNDLED PRICE.
    TektronixPGY-UFSUFS Protocol Decodes MIPI M-PHY UFS Protocol Decode software
    Tektronix012-0991-00GPIB Cable Double shielded
    Tektronix067-1686-02Power Measurement Deskew Fixture
    Tektronix119-8726-00TekVPI External Power Adapter (Replaces 119-7465-01) Replaces 119-7465-00 and 119-7465-01
    TektronixHCTEK54Transit Case Hard Transit Case (ACD4000B Soft Case is required for the DPO/MSO4000B, not required for the DPO/MSO5000)
    TektronixK420Instrument Cart
    TektronixDPO-UP MSOEMSO Upgrade Add 16 digital channels to a DPO5000B
    TektronixOpt. 10RLRecord Length Option 125M/Ch
    TektronixOpt. 5RLRecord Length Option 50M/Ch
    TektronixOpt. DJASoftware Option Jitter and Eye Analysis Tools - Advanced (DPOJET)
    TektronixOpt. ET3Software Option Ethernet Compliance Testing. Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture.
    TektronixOpt. MTMMask Testing ITU-T (64 Kb/s to 155 Mb/s), ANSI T1.102 (1.544 Mb/s to 155 Mb/s), Ethernet IEEE 802.3, ANSI X3.263 (125 Mb/s to 1.25 Gb/s). Refer to Data Sheet for complete specifications.
    TektronixOpt. SR-AEROAerospace Serial Triggering and Analysis (MIL-STD-1553) Enables triggering on packet-level information on MIL-STD-1553 buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time stamp information.
    TektronixOpt. SR-AUTOAutomotive Serial Triggering and Analysis (CAN/LIN/FlexRay) Enables triggering on packet-level information on CAN/LIN/FlexRay buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time stamp information.
    TektronixOpt. SR-COMPSoftware Option Computer Serial Triggering and Analysis (RS-232/422/485/UART)
    TektronixOpt. SR-DPHYAnalysis Option MIPI D-PHY DSI-1 and CSI-2 Decoding
    TektronixOpt. SR-EMBDSoftware Option Embedded Serial Triggering and Analysis (I2C, SPI)
    TektronixOpt. SR-USBSoftware Option USB Serial Triggering and Analysis (LS, FS, HS). Enables triggering on packet-level content for low-speed, full-speed, and high-speed USB serial buses.
    TektronixOpt. BRRBroadR-Reach Compliance Testing
    TektronixP5100AHigh Voltage Probe 100X, 500 MHz, 2.5 kV
    TektronixP6616MSO Probe 16-Channels
    TektronixP6701BOptical-to-Electrical Converter DC to 1 GHZ, 500-950 NM
    TektronixP6703BOptical-to-Electrical Converter DC to 1 GHZ, 1100-1650 NM
    TektronixRMD5000Rackmount Kit For DPO4000B, MSO4000B, MDO4000B/4000C, DPO5000B, MSO5000B Series
    TektronixOpt. SR-ENETEthernet Serial Triggering and Analysis 10BASE-T, 100BASE-TX, Enables triggering on packet-level information on Ethernet buses as well as analytical tools such as bus views, packet decoding, search tools, and packet decode tables with time stamp information.
    TektronixTAP15001.5 GHz Active Probe, TekVPI Interface MSO/DPO2000 Series requires TekVPI external power adapter (119-8726-00); one per oscilloscope.
    TektronixTAP25002.5 GHz Active Probe, TekVPI Interface
    TektronixTCP0020AC/DC Current Probe MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTCP0030AAC/DC Current Probe 120 MHz, 1 mA, 30 A, AC/DC. 5mm jaw. Requires TekVPI external power adapter (119-7465-01); one per oscilloscope. Replaces TCP0030.
    TektronixTCP0150AC/DC Current Probe 20 MHz, 150A AC/DC. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTDP0500High Voltage Differential Probe, 500 MHz, TekVPI Interface Probes terminate into 50 Ω but oscilloscope will automatically adjust to account for 1 MΩ input. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope. SILV600 Silver Care 600 extended warranty is available.
    TektronixTDP1000High Voltage Differential Probe, 1 GHz, TekVPI Interface MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTDP1500Differential Probe, 1.5 GHz, TekVPI Interface
    TektronixTDP3500Differential Probe, 3.5 GHz, TekVPI Interface
    TektronixTek-DPGTekVPI Deskew Pulse Generator Signal Source For Tektronix instruments that feature the TekVPI interface, including DPO/MSO/MDO3000 Series and DPO/MSO/MDO4000 Series oscilloscopes.
    TektronixTEK-USB-488GPIB to USB Adapter
    TektronixTHDP0100High Voltage Differential Probe 100 MHz, ±6000 V. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTHDP0200High Voltage Differential Probe 200 MHz, ±1500 V. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTMDP0200High Voltage Differential Probe 200 MHz, ±750 V. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTPP0500BPassive Voltage Probe 500 MHz, 10X, <4 pF
    TektronixTPP0502Passive Voltage Probe 500 MHz, 2X, 12.7 pF
    TektronixTPP0850High Voltage Probe 50X, 800 MHz, 2.5 kV
    TektronixTPP1000Passive Voltage Probe 1 GHz, 10X, 3.9 pF
    TektronixUSBPWRAutomated Compliance Test Solution Provides a complete set of measurements required for compliance testing to the IEC 62684 specification on the USB 2.0 Battery Charger Specification v1.1. Supported by 350 MHz MSO/DPO5000/7000 oscilloscopes.
    TektronixTPA-BNCTekVPI-BNC Interface Adapter Requires TekVPI external power adapter (119-7465-00); one per oscilloscope.
    TektronixOpt. MOSTMOST Compliance Testing MOST Essentials- Electrical Compliance and Debug Test Solution for MOST50 and MOST150 (requires DJA)
    TektronixOpt. PWRAnalysis Option Power Measurement and Analysis
    TektronixDPO5034B SVESignalVu Signal Analysis Software For DPO5034B. SignalVu Essentials Vector Signal Analysis Software
    TektronixOpt. USB2Software Option USB 2.0 Compliance Testing. Requires TDSUSBF (USB Test Fixture). 2 GHz bandwidth required for high-speed USB.
    TektronixOpt. DBDPO Demonstration Board
    TektronixDPOPWRAdvanced Power Measurement and Analysis Software V 2.1.0 Free Trial for evaluation. Requires WIN7-64 bit OS Scopes. Measures and analyzes phase angle, voltage harmonic, amplitude measurement, power dissipation and magnetic components at switching devices and supplies, SOA and Peak flux density measurements to view reliability issues, measure power quality, input capacitance, In Rush Current, precompliance test for MIL- 1399, EN61000-3-2 and AM14 standard and generates detailed test reports. Installing Advanced Power Analysis v2.1.0 will uninstall DPOPWR v1.0.13/v2.0.0 and install the new Advanced Power Analysis solution v2.1.0 automatically. Obtain new software or upgrade existing DPOWR (Win7) HERE.
    TektronixTEKSCOPEFL-BASTekScope Anywhere Waveform Analysis and Visualization Software, Floating License
    TektronixTEKSCOPEFL-DJATekScope Anywhere Waveform Analysis and Visualization with Advanced Jitter Analysis, Floating License
    TektronixDPO5034B SVPSignalVu Pulse Advanced Signal Analysis For DPO5034B. Requires Opt. SVE
    TektronixDPO5034B SVMSignalVu General Purpose Modulation Analysis For DPO5034B. Requires Opt. SVE
    TektronixDPO5034B SVTSignalVu Settling Time Measurements For DPO5034B. Requires Opt. SVE