Tektronix MSO2022B Mixed Signal Oscilloscope

20818.1 MFG #: MSO2022B
$0.00 / EA

QTY
  • Description
  • Options

Product Features

    Feature-rich Tools for Debugging Mixed Signal Designs
    Offering up to 200 MHz bandwidth and 1 GS/s sample rate, the MSO/DPO2000B Mixed Signal Oscilloscope Series delivers advanced debug features at an entry-level price. With up to 20 channels for analyzing analog and digital signals, you can quickly find and diagnose problems in complex designs. To capture long windows of signal activity while maintaining fine timing resolution, the MSO/DPO2000B offers a deep record length of 1 Mpoints standard on all channels. Debug faster and easier than ever before with Wave Inspector's unique ability to zoom, pan, play, pause and set marks — helping you to efficiently navigate through long records. This makes it an ideal choice when working with today's most common serial buses, such as I2C, SPI, RS-232/422/485/UART, CAN, and LIN.

    Comprehensive Features Speed Every Stage of Debug
    The MSO/DPO2000B Series offers a robust set of features to speed every stage of debugging your design — from quickly discovering an anomaly and capturing it, to searching your waveform record for the event and analyzing its characteristics and your device's behavior.

    Discover, Capture, Search, Analyze
    A waveform capture rate of 5,000 waveforms per second enables you to see glitches and other infrequent transients quickly, revealing the true nature of device faults. A digital phosphor display with intensity grading helps you discover the history of a signal's activity by intensifying areas of the signal that occur more frequently, providing a visual display of just how often anomalies occur. Discovering a device fault is only the first step. Next, you must capture the event of interest to identify root cause. The MSO/DPO2000B Series provides a complete set of triggers — including runt, logic, pulse width/glitch, setup/hold violation, serial packet, and parallel data — to help quickly find your event. The MSO/DPO2000B Series offers a comprehensive set of integrated analysis tools including waveform- and screen-based cursors, 29 automated measurements, and FFT analysis. Specialized application support for serial bus analysis is also available.

    P6316 Probe

    P6316 MSO Probe
    This unique probe design offers two eight-channel pods, simplifying the process of connecting to the device-under-test. When connecting to square pins, the P6316 can connect directly to 2 square pin headers spaced on tenth-inch centers. When more attachment flexibility is required, you can use the included flying lead sets and grabbers to clip onto surface mount devices or test points. The P6316 offers outstanding electrical characteristics applying only 8 pF of capacitive loading with 101 kΩ input impedance.

    Ease-of-Use and Connectivity Features

    • Wave Inspector® Controls Provide Easy Navigation and Automated Search of Waveform Data
    • FilterVu™ Variable Low-pass Filter Allows Removal of Unwanted Signal Noise while still Capturing High-frequency Events
    • 29 Automated Measurements, and FFT Analysis for Simplified Waveform Analysis
    • TekVPI® Probe Interface Supports Active, Differential, and Current Probes for Automatic Scaling and Units
    • USB 2.0 Host Port and Device Port
    • Optional 10/100 Ethernet Port

    Tektronix MSO2000B and DPO2000B Series Digital Phosphor/Mixed Signal Oscilloscopes

    DPO2002B
    70MHz, 1GS/s
    1M Memory, 2Ch.
    DPO2004B
    70MHz, 1GS/s
    1M Memory, 4Ch
    DPO2012B
    100MHz, 1GS/s
    1M Memory, 2Ch
    DPO2014B
    100MHz, 1GS/s
    1M Memory, 4Ch
    DPO2022B
    200MHz, 1GS/s
    1M Memory, 2Ch
    DPO2024B
    200MHz, 1GS/s
    1M Memory, 4Ch
    MSO2002B
    70MHz, 1GS/s
    1M Memory, 2+16 Ch
    MSO2004B
    70MHz, 1GS/s
    1M Memory, 4+16 Ch
    MSO2012B
    100MHz, 1GS/s
    1M Memory, 2+16 Ch
    MSO2014B
    100MHz, 1GS/s
    1M Memory, 4+16 Ch
    MSO2022B
    200MHz, 1GS/s
    1M Memory, 2+16 Ch
    MSO2024B
    200MHz, 1GS/s
    1M Memory, 4+16 Ch

    All Models Include: One 10X Passive Probe per Analog Channel (TPP0200 200 MHz probe for 100 and 200 MHz models, TPP0100 100 MHz probe for 70 MHz models), Installation and Safety Manual and Translated Front-panel Overlay, Documentation CD (063-4472-xx), OpenChoice® Desktop Software, Calibration certificates document measurement traceability to National Metrology Institute(s) and ISO9001 Quality System Registration, and Power Cord. MSO Models also Include: One P6316 16-channel logic probe and accessory kit, and accessory bag (016-2008-xx).

    • 200, 100, 70 MHz Bandwidth Models
    • 2 and 4 Analog Channel Models
    • 16 Digital Channels (MSO Series)
    • 1 GS/s Sample Rate on All Channels
    • 1 Megapoint Record Length on All Channels
    • 5,000 wfm/s Maximum Waveform Capture Rate
    • Suite of Advanced Triggers
    • 7 in. (180 mm) Widescreen TFT-LCD Color Display
    • Five-year warranty
    • View video introduction

    ManufacturerModelDescription
    TektronixDPO2AUTOAutomotive Serial Triggering and Analysis Enables triggering on packet level information on CAN and LIN buses as well as analytical tools such as bus views, packet decoding, search tools, and packet decode tables with timestamp information.
    TektronixDPO2CONNEthernet and Video Out Connectivity Module Adds Ethernet (10/100Base-T) and Video Out Port.
    TektronixTek-DPGTekVPI Deskew Pulse Generator Signal Source For Tektronix instruments that feature the TekVPI interface, including DPO/MSO/MDO3000 Series and DPO/MSO/MDO4000 Series oscilloscopes.
    Tektronix119-8726-00TekVPI External Power Adapter (Replaces 119-7465-01) Replaces 119-7465-00 and 119-7465-01
    TektronixTEK-USB-488GPIB to USB Adapter
    TektronixACD2000Soft Carrying Case
    TektronixHCTEK4321Hard Carrying Case Requires ACD2000/AC2100.
    TektronixTAP15001.5 GHz Active Probe, TekVPI Interface MSO/DPO2000 Series requires TekVPI external power adapter (119-8726-00); one per oscilloscope.
    TektronixTAP1500X21.5 GHz Active Probe, TekVPI Interface Bundle of two TAP1500 probes. Includes single accessory kit. Does not include individual probe cases. MSO/DPO2000 Series requires TekVPI external power adapter (119-8726-00); one per oscilloscope.
    Discontinued.
    TektronixTCP0020AC/DC Current Probe MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTCP0150AC/DC Current Probe 20 MHz, 150A AC/DC. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTCP2020AC/DC Current Probe DC to 50 MHz, 20 A DC, 100 A Peak Pulse. Direct BNC connection.
    TektronixP5100AHigh Voltage Probe 100X, 500 MHz, 2.5 kV
    TektronixP5100A-PKGHigh Voltage Probes 100X, 500 MHz, 2.5 kV, 10 Pack
    TektronixTCP404XLAC/DC Current Probe DC to 100 MHz, 30 Amps DC, 750 Amps DC derated with duty cycle (Requires TCPA400 Amplifier)
    TektronixTMDP0200High Voltage Differential Probe 200 MHz, ±750 V. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTHDP0100High Voltage Differential Probe 100 MHz, ±6000 V. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixTHDP0200High Voltage Differential Probe 200 MHz, ±1500 V. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixADA400AHigh-Gain Differential Preamplifier 100X, 10X, 1X, 0.1X. MSO/DPO2000 Series requires TekVPI external power adapter (119-7465-01); one per oscilloscope.
    TektronixP6316MSO Probe 16-Channel (two eight-channel pods). 8 pF of capacitive loading with 101 kΩ input impedance.
    NOTE: This is a spare MSO probe only. MDO3MSO is required for MSO capability.
    TektronixDPO2EMBDEmbeded Serial Triggering and Analysis Enables triggering on packet level information on I2C and SPI buses as well as analytical tools such as bus views, packet decoding, search tools, and packet decode tables with timestamp information. Only two-wire SPI support available on two-channel models.
    TektronixDPO2COMPComputer Serial Triggering and Analysis Enables triggering on packet level information on RS-232/422/485/UART buses as well as analytical tools such as bus views, packet decoding, search tools, and packet decode tables with timestamp information.
    TektronixTCP0030AAC/DC Current Probe 120 MHz, 1 mA, 30 A, AC/DC. 5mm jaw. Requires TekVPI external power adapter (119-7465-01); one per oscilloscope. Replaces TCP0030.
    TektronixDPO2BND2000B Series Application Bundle Includes three modules: DPO2AUTO, DPO2COMP, DPO2EMBD
    Save $835 over individually-priced options.