TestEquity
Refresh your bench. Save 10%. 3 categories. One order. Offer ends May 29. Shop The Promo
You’re in the right place. Techni-Tool and Jensen are now TestEquity. Learn more
 
QA Technology 100-PRP2508H
QA Technology

QA Technology 100-PRP2508H Probe, 0.100 Center, 0.250 Full Stroke, Triad, High SF, 100-25 Series

Our Part #10031237

Condition:New

Mfr Part #100-PRP2508H

$0.90EACH

  • Conventional probe designed for loaded board testing.
  • 0.100 center and 0.250 full stroke probe, part of QA Technology's 100-25 Series.
  • High Spring Force (SF) made of stainless steel material with a 300,000 cycle life.
  • Triad tip style (#08) provides the highest penetrating pressure for reliable testing on flat or domed test pads.
  • Tube material "P" nickel silver/id precious metal clad improves wear properties and offers < 20 mOhms resistance.
  • Working temperature range of -55°C to 120°C with lubrication. SS springs can be used up to 204°C without lubrication.

The 100-PRP2508H, a part of QA Technology's 100-25 Series, is a conventional probe designed for loaded board testing. Configured at a 0.100" center with a 0.250" stroke, the high force stainless steel spring ensures 300,000 cycles of dependable operation. Equipped with a Triad tip (#08), it provides reliable testing on flat or domed test pads. Internally, the tube maintains < 20 mOhms resistance for accurate measurements. Thanks to QA Technology's patented plunger geometry, you get reliable electrical contact every time. Works from -55°C to 120°C, or up to 204°C for unlubricated stainless steel springs.

Questions and Answers

What is the maximum voltage that QA Technology test probes and sockets can carry?
There is no specific upper voltage limit defined for test probes or socket/termination pins. However, the spacing between probes and the dielectric strength of the probe plate must be evaluated. Probe plate materials that absorb moisture should be avoided. Apply test voltage to the fixture or DUT only after the fixture is engaged and the probes are fully compressed against the DUT. Energizing the probes before they make contact can cause arcing, which may damage or melt the probe tips.

Can QA Probes be used for Hipot testing?
Yes. Hipot testing, short for High Potential testing and also known as a Dielectric Withstanding Voltage (DWV) test, subjects a device to a voltage higher than its normal operating level. The purpose is to confirm that the device’s insulation can withstand this elevated voltage without breaking down, ensuring it provides adequate protection against electrical shock. This method is commonly applied to PCBs, transformers, electric motors, finished appliances, cables, and other wired or wireless assemblies.


BrandQA Technology
TypeProbe
Series100-25 Series
Centers0.100
Stroke Length0.250 Full Stroke
Tip StyleTriad
Spring ForceHigh
MaterialNickel silver/ID precious metal clad
Resistance< 20 MΩ
 
$0.90EACH