TestEquity
 
QA Technology 050-PRP2561S
QA Technology

QA Technology 050-PRP2561S Probe, 0.050 Center, 0.250 Full Stroke, Blade, Standard SF, 050-R25 Series

Our Part #10061945

Condition:New

Mfr Part #050-PRP2561S

$3.40EACH

  • Conventional probe designed for loaded board testing.
  • 0.050 center and 0.250 full stroke probe, part of QA Technology's 050-R25 Series.
  • Standard Spring Force (SF) made of musical wire material with a 1,000,000 cycle life.
  • Blade tip style (#61) is used for open or solder pasted holes/vias.
  • Tube material "P" nickel silver/id precious metal clad improves wear properties and offers < 20 mOhms resistance.
  • Working temperature range of -55°C to 120°C with lubrication. SS springs can be used up to 204°C without lubrication.

The 050-PRP2561S is a in-circuit (ICT) and functional (FCT) probe in QA Technology's 050-R25 Series lineup. Configured at 0.050" center with a 0.250" stroke, it delivers standard spring force through musical wire construction, rated for 1,000,000 cycles. The Blade tip (#61) handlesopen or solder pasted holes/vias. The tube construction keeps resistance < 20 mOhms while maximizing wear life. QA Technology's angled plunger tail design maintains consistent contact between cycles. Operating range: -55°C to 120°C (up to 204°C without lubrication for SS springs).

Questions and Answers

What is the maximum voltage that QA Technology test probes and sockets can carry?
There is no specific upper voltage limit defined for test probes or socket/termination pins. However, the spacing between probes and the dielectric strength of the probe plate must be evaluated. Probe plate materials that absorb moisture should be avoided. Apply test voltage to the fixture or DUT only after the fixture is engaged and the probes are fully compressed against the DUT. Energizing the probes before they make contact can cause arcing, which may damage or melt the probe tips.

Can QA Probes be used for Hipot testing?
Yes. Hipot testing, short for High Potential testing and also known as a Dielectric Withstanding Voltage (DWV) test, subjects a device to a voltage higher than its normal operating level. The purpose is to confirm that the device’s insulation can withstand this elevated voltage without breaking down, ensuring it provides adequate protection against electrical shock. This method is commonly applied to PCBs, transformers, electric motors, finished appliances, cables, and other wired or wireless assemblies.


BrandQA Technology
TypeProbe
Series050-R25 Series
Centers0.050
Stroke Length0.250 Full Stroke
Tip StyleBlade
Spring ForceStandard
MaterialNickel silver/ID precious metal clad
Resistance< 20 MΩ
 