$EACH
- Description
- Specifications
- Documents
- UL listed
- Sensor power induced from line voltage
- Self-gripping split-core design for fast installation
- For use in indoor environments
A split-core AC current sensor responsive over the range of 60 to 600 amps AC for use with U12, UX120, and ZW data loggers with external input channels. With an input current of AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag.
- Range: 2 to 20, 5 to 50, 10 to 100, 20 to 200, 60 to 600 Amps
- Accuracy with H8: ±5.0% of full scale
- Accuracy with U12: ±4.5% of full scale
- Accuracy with UX120-006M, MX1104 and MX1105: ±2.1% of full scale
- Input current: AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag
- Voltage rating: 600 VAC
- Construction and operating environment: Molded plastic housing for indoor use per UL508; pivoting leg (leg on CTV-D and CTV-E units is fully removable); UL listed.
- Cable length: 1.8m cable (6 foot)
Brand:Â HOBO by Onset
Type:Â Transformer
For Use With:Â U12, UX120, ZW Series Data Loggers
Input Current:Â 60-600 A
$EACH