$EACH
- Description
- Specifications
- Documents
Current Clamp Sensor
- Displays current waveforms up to 150 A
- Connects directly to oscilloscope BNC input terminal
- Connects directly to the MEMORY HiCORDER to provide waveform monitoring
- An optional power supply is available for use with oscilloscopes that do not provide probe power
- Supplied w/Carrying case
- 1-Year Warranty
Wide-band, large current probe allows direct input to oscilloscope
Basic specificationsFrequency band width | DC to 10 MHz (-3 dB) |
Rise time | =<35 ns |
Noise level | 25 mA rms max. (band width limited to 20 MHz) |
Continuous allowable input | 150 A rms (requires derating at frequency) |
Max. allowable peak input | 300 A peak (non continuous), 500 A peak (pulse width: 30 μs or shorter) |
Amplitude accuracy | ±1.0 % rdg. ±1 mV f.s. (DC, 45 to 66 Hz, 0 to 150 A rms) ±2.0 % rdg. (DC, 45 to 66 Hz, 150 A to 300 A peak) |
Output rate | 0.01 V/A (use with a device having a 1 M-ohm input resistance or higher) |
Max. rated voltage to earth | 600 V CAT II, 300 V CAT III (insulated wire) |
Please see Data Sheet for complete specifications.
Brand:Â Hioki
$EACH